An air conditioner leaks when the water it removes from the air can't leave the system. The usual causes are a blocked condensate drain, a frozen coil that thaws, a damaged or cracked drain pan, poor installation slope, dirty filters or a low refrigerant charge. Less obvious causes include a failed condensate pump, a leaking refrigerant line sweating in humid air and ductwork condensation. Switch the unit off if water is near electrics, then find the cause before restarting.
A few drips from an AC feel like a nuisance. A stained ceiling, a wet floor or water running down the wall feels like a crisis. Either way, the question is the same: where is the water coming from, and why can't it get out? The obvious answer is a blocked drain, and it's often right. But when the leak returns after you've cleaned the drain, or appears in an odd place, the cause is usually one of the hidden ones below. This guide explains each, how to tell them apart, and what to do. For a short summary, see our quick page on why your air conditioner is leaking.
Cooling air also removes moisture from it. As warm, humid air passes over the cold evaporator coil, water condenses on the coil, drips into a pan and flows out through a drain line. In Abu Dhabi's humid summers, a unit can remove a surprising amount of water every day, which is why even a small drainage problem shows up quickly. A leak means the water isn't leaving through the intended route.
This is the most common cause. Dust, algae and slime build up in the drain line until water backs up and overflows from the indoor unit. The US Department of Energy notes that clogs in the drain channels stop the unit removing humidity and can cause moisture damage, and suggests occasionally running a stiff wire through the channels to clear them. If the water is dripping from the front or bottom of the indoor unit and the drain pipe outside runs dry, a blockage is the likely reason. If the blockage keeps returning, the drain may need a professional flush, and our AC cleaning service includes drain cleaning.
If ice forms on the coil, it eventually melts and floods the drain pan faster than it can empty. The ice itself is a symptom. Restricted airflow from a dirty filter, a failing fan, or low refrigerant can all make the coil too cold. You might see ice on the pipes or the front of the indoor unit, notice weak cooling, then see water once the unit cycles off. Don't keep running a frozen unit, because it can damage the compressor. Our article on why an AC coil freezes explains the causes in detail.
A clogged filter restricts airflow, which can cool the coil too much and cause icing, then leaks. This is one of the cheapest causes to fix. The Department of Energy advises cleaning or replacing filters about every month or two in the cooling season, and more often in dusty conditions, which suits Abu Dhabi. Dirty filters also push up energy use, so it's worth checking them before assuming a larger fault. Our guide on how dirty AC filters affect airflow explains the effect.
The drain pan sits under the coil and catches condensation. Over time, pans in older units can crack, corrode or shift out of position, so water misses the drain outlet and leaks into the casing and out of the unit. Because the pan is hidden inside the indoor unit, you only see the result: water in unexpected places, often from the underside or back. A damaged pan usually needs replacement or repair by a technician, and it's easy to miss during a DIY check.
Condensate drains work by gravity, so the pipe must slope downhill all the way. If the indoor unit is tilted the wrong way, or the drain hose has sagged, water pools in a low spot and can overflow or back up. This is a common reason why a new or recently moved AC leaks, and why cleaning doesn't cure it. The fix is to correct the unit's level and re-lay the drain, ideally supported along its length. If your unit was recently installed or relocated, our AC installation team can check the levels and the drain run.
A low charge lowers the pressure in the system, which can make the evaporator coil colder than it should be and cause icing. When the ice melts, the pan overflows. Low refrigerant also reduces cooling, so a unit that leaks and doesn't cool well may be short of charge. A low charge means a leak in the sealed system, so topping up is only a temporary measure unless the leak is found and repaired. The Department of Energy lists checking the refrigerant charge and leaks as a technician task. See our AC gas refill page for how we handle this.
Where the indoor unit sits below the drain outlet, such as in a ceiling void or a basement, a small pump moves the water up and out. If the pump fails, or its float switch sticks, the pan overflows. You may hear no pump noise, or hear it running constantly. Because the pump has electrical parts, replacing it is work for a technician, and a safety float switch is a good addition where a leak could cause damage.
Not every drip is from the drain. Cold refrigerant pipes and ductwork sweat if the insulation is damaged, missing or poorly fitted, especially in hot, humid roof voids. The water drips from the pipe run or the duct, often far from the unit itself, and can stain ceilings in several places. The fix is to repair or replace the insulation and seal the joints. In central and ducted systems, duct problems can also affect airflow, so see our AC duct cleaning page.
Some water is normal. Split units drain condensate outside, and the outdoor unit and its pipe can drip during operation, particularly in humid weather. If water runs down a wall or drips onto a walkway, the issue may be the drain pipe's position or a damaged hose, not a fault in the AC itself. In apartments, check with building management, since external drainage can affect neighbours or common areas.
Likely blocked drain or dirty filter
Frozen coil: airflow or refrigerant problem
Check slope and drain pipe position
Damaged insulation or sweating ducts
Water damages ceilings, paint, flooring and furniture, and wet electrics are a safety risk. It also creates damp conditions for mould. The US Environmental Protection Agency advises drying water-damaged areas within 24 to 48 hours to prevent mould growth, and notes that porous materials such as ceiling tiles and carpet may have to be thrown away if they become mouldy. That's a good reason to act the same day, instead of waiting for the leak to stop on its own.
For a diagnosis and repair, our AC repair team will find the cause, explain it and quote a fixed price before work starts.
Most leaks are preventable with simple habits. Clean or replace filters regularly, keep the outdoor unit and its drain clear, and have the drain and coil cleaned during an annual service. Check that insulation on exposed pipes is intact, and don't ignore small drips, since they often get worse. In a dusty city, regular servicing keeps drains and coils from clogging. For routine servicing, our AC maintenance service includes drain and coil checks.
If water has soaked into a ceiling, wall or carpet, dry it quickly with fans and ventilation and wipe hard surfaces with detergent and water. The EPA also recommends keeping indoor humidity below 60 percent, ideally between 30 and 50 percent, which a working AC helps to do. If a ceiling is stained, bulging or smells musty, ask a professional to check before repainting, because paint over a damp surface will peel. For repainting after repair, our interior painting team can help.
If your AC is leaking and you can't tell why, message or call ALHUD Technical LLC. We'll trace the cause, fix it properly and give you a fixed quote before we start. If you'd like us to look at the wider system, our HVAC services page lists what we cover.
The most common cause is a blocked condensate drain. Other causes include a frozen coil that melts, a dirty filter, a cracked drain pan, poor installation slope, low refrigerant, a failed condensate pump or insulation damage on pipes and ducts.
Some dripping outside from the drain pipe is normal when the unit removes humidity. Water dripping or running inside the home is not normal and means the condensate isn't draining properly.
Yes. A clogged filter restricts airflow, which can make the coil too cold and cause ice. When the ice melts, the drain pan can overflow.
Yes. Low refrigerant can make the evaporator coil too cold, causing ice that later melts and overflows. It also means there's a leak in the sealed system, which needs a technician.
Yes, especially if water is near sockets, switches or the distribution board. Switch it off, contain the water and find the cause before restarting.
You can sometimes clear a visible drain by running a stiff wire through it, as the US Department of Energy suggests. If the blockage keeps returning, a professional drain flush is better.
Often because ice has formed on the coil while running and melts after the unit stops. Check the filter and airflow, and call a technician if ice returns.
Yes. The US Environmental Protection Agency advises drying water-damaged areas within 24 to 48 hours to prevent mould growth, so deal with leaks the same day.
Call if the leak returns after cleaning the filter and drain, you see ice more than once, cooling is weak, water is near electrics, or the unit was recently installed or moved.